COMMERCIAL SPACE COLLECTIONS

Solid Surface
Commercial
Space Products

Choose the element.
Resolve its connections.

Custom solid-surface elements for ceilings, walls and column surrounds. Confirm the substrate, fixing and access before the visible form is released.

Concept illustration of architectural elements in a commercial lobby
Concept illustration / architectural elements

C02 / PRODUCT REFERENCES

Start with the application.
Compare the right elements.

Explore current solid-surface product references. Compare the application, form and interface conditions to find a starting point for your project.

Product scope and final details follow the selected item.

C03 / APPLICATION SELECTION

One material language.
Different build decisions.

Concept illustration of curved solid surface ceiling feature

Ceilings + overhead features

Confirm support responsibility, fixing points and maintenance access.

View reference
Concept illustration of interior wall cladding

Wall cladding

Confirm surveyed substrate, adjoining finishes and panel replacement.

View reference
Concept illustration of circular column surrounds

Column surrounds

Confirm available clearance, split positions and installation sequence.

View reference

C04 / INTERFACE MAP

A clean radius starts with
a confirmed substrate.

Illustrative assembly / final fixing and geometry require project approval
01

Surveyed substrate

Confirm the actual profile, out-of-plumb variation and available clearance.

Review conditions

Record surveyed centre lines, floor-to-ceiling conditions and adjoining finishes. Overlay the surveyed substrate profile with the intended finished radius before fixing the panel line.

Record to confirm: Surveyed section, profile and available-clearance record.

02

Fixing provision

Agree the support detail, allowable fixing zone and approval owner.

Review conditions

Confirm the substrate and permitted fixing locations, support responsibility, loads and installation method with the responsible project team. Release the selected fixing detail only after the named owner approves it.

Record to confirm: Approved fixing detail and responsibility confirmation.

03

Split + joint

Coordinate seam locations with module size and installation sequence.

Review conditions

Review panel divisions, visible joint positions, tolerances and joining method against the surveyed geometry and receiving route. A continuous appearance does not establish a joint-free assembly.

Record to confirm: Panel split and joint schedule linked to the approved revision.

04

Access + replacement

Keep required services reachable and plan panel removal.

Review conditions

Confirm which panels can be removed, tool clearance, service access zones and the replacement route. Check that fixings and adjacent finishes allow access without dismantling unrelated work.

Record to confirm: Access-zone and removable-panel review.

C05 / MATERIALS + SUPPORT

A formed surface.
A project-specific support strategy.

Concept close-up of a formed solid-surface edge
Material detail concept
Illustrative column surround assembly with backing and fixings
Illustrative assembly / not a universal construction
01

Surface + edge

Confirm material, finish, forming radius and visible joint treatment.

02

Selected backing + fixing

Select the support and fixing method for the approved geometry and loads.

03

Building connection

Review the substrate and adjoining finishes with the responsible project team.

C06 / PROJECT RISK MAP

Resolve the dependency.
Prevent the site change.

Design radius

Design radius

Proposed outer form and visual appearance.

Surveyed profile

Surveyed profile

Actual substrate profile and available clearance.

Revised panel line

Revised panel line

Adjusted panel line and support strategy.

Illustrative coordination sequence

Risk

The outer radius is fixed before the substrate is surveyed.

Consequence

Fixing space or service access is lost.

Control point

Overlay survey, support, joints and access zones before release.

Record to confirm

Surveyed section + fixing detail + approved revision.

A continuous appearance is treated as a joint-free assembly
Risk

The visual concept is taken as a promise of an uninterrupted panel.

Consequence

Manufacturing, transport or installation requires a split that appears late on site.

Control point

Agree panel size, joint positions and the installation sequence before manufacturing.

Record to confirm

Approved panel division drawing + joint detail + module schedule.

A formed module cannot reach its final position
Risk

Final dimensions are released without checking the packaged receiving route.

Consequence

The module cannot clear the lift, landing or doorway, delaying installation.

Control point

Prove the complete route with packed module dimensions and gross weight; revise modules before release.

Record to confirm

Route measurements + module/packing schedule + agreed handling sequence.

C07 / BEFORE WE BUILD

Freeze the coordinated detail.
Then release manufacture.

Sample dimensioned column-surround review drawing
Sample review record / no completed project verification implied
Project
Commercial space element
Drawing
Reference detail
Revision
For manufacture
Scope
Geometry, support, joints, interfaces and access
Approval
Confirmed by project owner
01

Survey + geometry

Actual profile, centre lines, clearances and adjacent conditions.

02

Surface + support

Panel split, substrate detail, fixing method and material.

03

Interfaces + responsibilities

Service openings, access zones and named approval owners.

04

Module + receiving route

Module size, packed dimensions, gross weight and delivery route.

Plan the module.
Prove the route.

Illustrative receiving entrance
Concept illustration / receiving condition

Ground floor

Receiving opening, unloading and handling route.

Route conditions

Confirm the receiving floor and the unloading point, door and corridor clearances, delivery vehicle access, handling method and responsible team before release. Check the packed module through every turn and doorway.

Illustrative elevator

Elevator

Door and cabin dimensions, load limit and receiving floor.

Route conditions

Record the elevator door width and height, cabin width, depth and height, rated load and receiving floor. Check packaged module dimensions and gross weight, including handling equipment, against the usable lift space and load limit.

Illustrative staircase route

Stairs

Clear width, landings, headroom and turning dimensions.

Route conditions

Measure stair clear width, landing size, clear headroom and every turning dimension. Review the packaged module envelope and carrying or lifting method through the complete route; do not rely only on its final installed dimensions.

Illustrative module packing

Assembly

Module joints, packed size, gross weight and lifting sequence.

Route conditions

Freeze module and packaging dimensions, module IDs and gross weight. Agree unloading, handling and lifting responsibility, joining method, assembly and installation order, temporary holding area and working window with the site team.

Crate size alone does not define a deliverable module.

C08 / READY TO QUOTE

Bring the reference.
Show us where it belongs.

Share the element, intended location and available drawings. Identify what is confirmed and what still needs coordination.

Application + quantity

Tell us what you are planning.

Drawing or reference

Share plans, sketches or similar projects.

Substrate + interfaces

Confirm what is known and what needs review.

Receiving floor + target date

Include access, handling and your programme.